Human Resistin enzyme-linked immunoassay kit
概述
产品名称
Human Resistin enzyme-linked immunoassay kit
产品类型
Elisa Kit
灵敏度
0.33 pg/ml (50 μl);0.48 pg/ml (10 μl);
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0118 | 0.0113 | 0.0116 | |
| 13.72 | 0.0165 | 0.0175 | 0.0170 | 0.0055 |
| 41.15 | 0.0270 | 0.0278 | 0.0274 | 0.0159 |
| 123.46 | 0.0605 | 0.0604 | 0.0605 | 0.0489 |
| 370.37 | 0.1887 | 0.1819 | 0.1853 | 0.1738 |
| 1111.11 | 0.5823 | 0.5926 | 0.5875 | 0.5759 |
| 3333.33 | 1.9340 | 1.8680 | 1.9010 | 1.8895 |
| 10000.00 | 4.2792 | 4.3434 | 4.3113 | 4.2998 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (pg/ml) | 173.5 | 899.9 | 3107.1 | 179.8 | 932.5 | 3171.0 |
| Standard Deviation | 6.8 | 32.8 | 125.6 | 3.0 | 17.6 | 149.7 |
| Coefficient of Variation (%) | 3.9 | 3.6 | 4.0 | 1.7 | 1.9 | 4.7 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 20 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入 3 个不同浓度水平的人 Resistin,未加人 Resistin 的血清作为本底,计算回收率。回收率的范围从 90 % 至 116 %,平均回收率为 103%。
样本值
| Sample Matrix | Sample Evaluated | Range (ng/ml) | Detectable (%) | Mean of Detectable (ng/ml) |
|---|---|---|---|---|
| Serum | 30 | 0.81-34.93 | 100 | 18.17 |
应用本试剂盒,检测 30 个健康志愿者的血清样本,志愿者的用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
实验类型
Sandwich Elisa
种属反应性
Human
检测方法
Colorimetric
操作时长
120min
标准曲线梯度
7点/3倍
孵育次数
2
可检测样本
可溶性物质的液相样品。例如:血清,血浆,细胞培养上清,组织研磨液等。
加样体积
50 μl/10 μl
产品特性
储存条件
存储于 2-8 ℃
靶点
功能
抵抗素,也称为ADSF和FIZZ3,是一种分泌肽激素,作为非共价三聚体或二硫键连接的同六聚体循环。抵抗蛋白由白色脂肪细胞、脾细胞、星形胶质细胞和前垂体上皮表达。它阻断脂肪细胞对胰岛素刺激的葡萄糖摄取,并促进肝细胞的葡萄糖释放。高循环胰岛素水平会诱导抵抗蛋白分泌,进而抑制胰岛素的作用。