Human Antithrombin III/AT III enzyme-linked immunoassay kit(one step)
概述
产品名称
Human Antithrombin III/AT III enzyme-linked immunoassay kit(one step)
产品类型
Elisa Kit
灵敏度
0.32 ng/ml(10 μl)
| ng/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0114 | 0.0110 | 0.0112 | |
| 1.37 | 0.0200 | 0.0207 | 0.0204 | 0.0092 |
| 4.12 | 0.0413 | 0.0449 | 0.0431 | 0.0319 |
| 12.35 | 0.1168 | 0.1128 | 0.1148 | 0.1036 |
| 37.04 | 0.3379 | 0.3194 | 0.3287 | 0.3175 |
| 111.11 | 0.9453 | 0.9712 | 0.9583 | 0.9471 |
| 333.33 | 2.3420 | 2.4280 | 2.3850 | 2.3738 |
| 1000.00 | 3.9570 | 3.9835 | 3.9703 | 3.9591 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (ng/ml) | 22.4 | 108.9 | 363.2 | 19.3 | 98.4 | 338.4 |
| Standard Deviation | 1.1 | 5.2 | 17.4 | 0.4 | 2.2 | 8.7 |
| Coefficient of Variation (%) | 5.0 | 4.7 | 4.8 | 1.9 | 2.2 | 2.6 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 20 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入 3 个不同浓度水平的人 Antithrombin III/ATIII,未加人 Antithrombin III/ATIII 的血清作为本底,计算回收率。回收率的范围从 83 % 至 117 %,平均回收率为 101%。
样本值
| Sample Matrix | Sample Evaluated | Range (μg/ml) | Detectable (%) | Mean of Detectable (μg/ml) |
|---|---|---|---|---|
| Serum | 30 | 169.32-423.79 | 100 | 306.49 |
应用本试剂盒,检测 30 个健康志愿者的血清样本,志愿者的用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
实验类型
Sandwich Elisa
种属反应性
Human
检测方法
Colorimetric
操作时长
60min
标准曲线梯度
7点/3倍
孵育次数
2
可检测样本
可溶性物质的液相样品。例如:血清,血浆,细胞培养上清,组织研磨液等。
加样体积
10 μl
产品特性
储存条件
存储于 2-8 ℃
靶点
UNIPROT
功能
蛇苋C1,也称为抗凝血酶III,是主要的血浆蛇苋,抑制凝血酶和Xa因子等血液凝固蛋白酶。
同靶点&同通路的产品
浙公网安备 33019202000643号