Human Prealbumin/Transthyretin enzyme-linked immunoassay kit(one step)
Rmb: 4500 特惠
产品规格
Safety datasheet
概述
产品名称
Human Prealbumin/Transthyretin enzyme-linked immunoassay kit(one step)
产品类型
Elisa Kit
灵敏度
0.02 ng/ml (10 μl)
| ng/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0095 | 0.0098 | 0.0097 | |
| 3.13 | 0.0895 | 0.0823 | 0.0859 | 0.0763 |
| 6.25 | 0.1597 | 0.1545 | 0.1571 | 0.1475 |
| 12.50 | 0.3028 | 0.3084 | 0.3056 | 0.2960 |
| 25.00 | 0.6030 | 0.5964 | 0.5997 | 0.5901 |
| 50.00 | 1.1280 | 1.1260 | 1.1270 | 1.1174 |
| 100.00 | 1.9260 | 1.8610 | 1.8935 | 1.8839 |
| 200.00 | 3.0040 | 2.9850 | 2.9945 | 2.9849 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (ng/ml) | 4.2 | 19.3 | 58.0 | 4.5 | 19.9 | 59.2 |
| Standard Deviation | 0.2 | 0.9 | 2.8 | 0.1 | 0.6 | 2.4 |
| Coefficient of Variation (%) | 4.7 | 4.5 | 4.8 | 2.4 | 3.1 | 4.0 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 22 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康血清加入3个不同浓度水平的人Prealbumin/Transthyretin,未加入人Prealbumin/Transthyretin的血清作为本底,计算回收率。
回收率的范围从83%至115%,平均回收率为97%。
样本值
| Sample Matrix | Sample Evaluated | Range (μg/ml) | Detectable (%) | Mean of Detectable (μg/ml) |
|---|---|---|---|---|
| Serum | 30 | 227.44-506.95 | 100 | 378.79 |
应用本试剂盒,检测 30 个健康志愿者的血清样本,志愿者的用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
实验类型
Sandwich Elisa
种属反应性
Human
检测方法
Colorimetric
操作时长
60min
标准曲线梯度
7点
孵育次数
2
可检测样本
血清,血浆
加样体积
10 μl
产品特性
储存条件
存储于 2-8 ℃
靶点
UNIPROT
功能
转甲状腺素(TTR),前称甲状腺素结合前白蛋白,是一种55 kDa的同源特质,含有14-15 kDa的单体,存在于血浆中。TTR负责运输甲状腺激素T4和视黄醇结合蛋白(RBP)。由于肾小管中TTR复合物的再摄取,TTR减缓了肾脏清除T4和RBP的速度。TTR也存在于包括大脑在内的组织中。许多人类多态性与家族性淀粉样多发性神经病(FAP)中发现的聚集体相关。成熟人类TTR在氨基酸串行上分别与小鼠和大鼠TTR共享83%的同性。
同靶点&同通路的产品