产品名称
Human Adiponectinenzyme-linked immunoassay kit(one step)
产品类型
Elisa Kit
灵敏度
0.14 ng/ml (10 μl)
| ng/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0079 | 0.0072 | 0.0076 | |
| 15.63 | 0.0964 | 0.0988 | 0.0976 | 0.0901 |
| 31.25 | 0.1636 | 0.1991 | 0.1814 | 0.1738 |
| 62.50 | 0.3482 | 0.3617 | 0.3550 | 0.3474 |
| 125.00 | 0.7514 | 0.7524 | 0.7519 | 0.7444 |
| 250.00 | 1.5100 | 1.5200 | 1.5150 | 1.5075 |
| 500.00 | 2.0590 | 2.4110 | 2.2350 | 2.2275 |
| 1000.00 | 3.6840 | 3.3470 | 3.5155 | 3.5080 |
精度
| Intra-assay Precision | Inter-assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (ng/ml) | 13.5 | 75.9 | 218.3 | 16.5 | 79.5 | 230.5 |
| Standard Deviation | 0.9 | 5.8 | 13.3 | 1.2 | 5.7 | 9.6 |
| Coefficient of Variation (%) | 6.7 | 7.6 | 6.1 | 7.1 | 7.1 | 4.2 |
板内精密度:3 个已知浓度的样本酶标板内重复测定 20 次,评估酶标板内的精密度。
板间精密度:3 个已知浓度的样本酶标板间重复检测 6 次,评估酶标板间的精密度。
加标回收
健康人血清加入 3 个不同浓度水平的人 Adiponectin,未加人 Adiponectin 的血清作为本底,计算回收率。回收率的范围从 87 % 至 119 %,平均回收率为 103 %。
样本值
| Sample Matrix | Sample Evaluated | Range (μg/ml) | Detectable (%) | Mean of Detectable (μg/ml) |
|---|---|---|---|---|
| Serum | 30 | 1.63-6.61 | 100 | 3.93 |
应用本试剂盒,检测 30 个健康志愿者的血清样本,志愿者的用药史不详。n.d. = 测不到浓度值。样本的浓度值低于灵敏度被认为测不到浓度值。
实验类型
Sandwich Elisa
种属反应性
Human
检测方法
Colorimetric
操作时长
60min
标准曲线梯度
7点
孵育次数
2
可检测样本
可溶性物质的液相样品。例如:血清,血浆,细胞培养上清,组织研磨液等。
加样体积
50 μl/10 μl
产品特性
储存条件
存储于 2-8 ℃
靶点
UNIPROT
功能
脂联素(也称为 30 kDa 脂肪细胞补体相关蛋白,Acrp30)是一种脂肪细胞来源的蛋白质,对代谢和炎症具有广泛的旁分泌和内分泌作用。它促进脂肪细胞分化、脂肪酸分解代谢和胰岛素敏感性,与肥胖、2 型糖尿病和动脉粥样硬化形成呈负相关。脂联素结合成 70 kDa 非共价连接的三聚体,这些三聚体通过二硫键结合成中等分子量六聚体,然后结合成 >300 kDa 高分子量低聚体。